448188-421 - HP ProLiant DL585 G5 8356 2.3GHz Quad Core 4P Rack Server

448188-421

 
 
Related products
 
 
Expansion slots
Expansion slots
9 total slots: (3) x8 PCI-Express; (4) x4 PCI-Express; (2) PCI-X (100MHz); One slot populated with the Smart Array P400 Controller
9 total slots: (3) x8 PCI-Express; (4) x4 PCI-Express; (2) PCI-X (100MHz); One slot populated with the Smart Array P400 Controller
9 total slots: (3) x8 PCI-Express; (4) x4 PCI-Express; (2) PCI-X (100MHz); One slot populated with the Smart Array P400 Controller
Memory
Memory
PC2-5300 Registered DIMMs at 667 MHz; PC2-6400 Registered DIMMs at 800 MHz
PC2-5300 Registered DIMMs at 667 MHz
PC2-5300 Registered DIMMs at 667 MHz
Memory slots
32 DIMM slots
32 DIMM slots
32 DIMM slots
Internal cache
512 KB integrated level 2 cache per core; 2 or 6 MB shared level 3 cache per processor (depends on model)
2 MB shared L3 cache per processor
2 MB shared L3 cache per processor
Networking
Network controller
Two embedded NC371i Multifunction Gigabit Network Adapters with TCP/IP Offload Engine, including support for Accelerated iSCSI through an optional Licensing Kit
Network interface
Two embedded NC371i Multifunction Gigabit Network Adapters with TCP/IP Offload Engine, including support for Accelerated iSCSI through an optional Licensing Kit
Two embedded NC371i Multifunction Gigabit Network Adapters with TCP/IP Offload Engine, including support for Accelerated iSCSI through an optional Licensing Kit
Ports
External I/O ports
Serial - 1; Pointing Device (Mouse) - 1; Video - 1 front, 1 rear; Keyboard - 1; USB Port (2.0) - 2 front, 2 rear, 1 internal; iLO2 Remote Management – 1; Network RJ-45 - 2
Serial - 1; Pointing Device (Mouse) - 1; Video - 1 front, 1 rear; Keyboard - 1; USB Port (2.0) - 2 front, 2 rear, 1 internal; iLO2 Remote Management – 1; Network RJ-45 - 2
Serial - 1; Pointing Device (Mouse) - 1; Video - 1 front, 1 rear; Keyboard - 1; USB Port (2.0) - 2 front, 2 rear, 1 internal; iLO2 Remote Management – 1; Network RJ-45 - 2
Power
Power availability
910 W (at 100 VAC), 1300 W (at 200 VAC)
910 W (at 100 VAC), 1300 W (at 200 VAC)
910 W (at 100 VAC), 1300 W (at 200 VAC)
Power features
910W (low line), 1300W (high line) with 12V main output. Size is 2.8"(H) X 4.9"(W) X 7.5"(L). NOTE: One Hot Plug Power Supply ships with Standard Models (optional Redundant Hot Plug Power Supply Option Kit available). High Performance models ship with two Hot Plug Power Supplies.
910W (low line), 1300W (high line) with 12V main output. Size is 2.8"(H) X 4.9"(W) X 7.5"(L). NOTE: One Hot Plug Power Supply ships with Standard Models (optional Redundant Hot Plug Power Supply Option Kit available). High Performance models ship with two Hot Plug Power Supplies.
910W (low line), 1300W (high line) with 12V main output. Size is 2.8"(H) X 4.9"(W) X 7.5"(L). NOTE: One Hot Plug Power Supply ships with Standard Models (optional Redundant Hot Plug Power Supply Option Kit available). High Performance models ship with two Hot Plug Power Supplies.
Power requirements
90 - 132 VAC, 180 - 264 VAC, 47 to 63 Hz
90 - 132 VAC, 180 - 264 VAC, 47 to 63 Hz
90 - 132 VAC, 180 - 264 VAC, 47 to 63 Hz
Processor
Chipset
nVidia NForce Professional 2200 and 2050 chipsets, and AMD-8132 chipset
nVidia NForce Professional 2200 and 2050 chipsets, and AMD-8132 chipset
nVidia NForce Professional 2200 and 2050 chipsets, and AMD-8132 chipset
Processor speed
2.30 GHz
2.30 GHz
Multiple processor
HP ProLiant DL585 G5 servers can support 2 or 4 processors.
HP ProLiant DL585 G5 servers can support 2 or 4 processors.
HP ProLiant DL585 G5 servers can support 2 or 4 processors.
Processor upgrade
HP ProLiant DL585 G5 servers can support 2 or 4 processors.
HP ProLiant DL585 G5 servers can support 2 or 4 processors.
HP ProLiant DL585 G5 servers can support 2 or 4 processors.
Rack
Rack mounting
HP ProLiant DL585 G5 rack models provide tool-free support for racks with square or round mounting holes (including Compaq/HP 7000, 9000, 10000, HP/E series, H9 series and third party racks) with an adjustment range from 24" - 36" in depth. The ambidextrous cable management arm can be mounted on either the left or right side for improved cable management. HP ProLiant DL585 G5 in Telco Racks Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option kit from Rack Solutions.
HP ProLiant DL585 G5 rack models provide tool-free support for racks with square or round mounting holes (including Compaq/HP 7000, 9000, 10000, HP/E series, H9 series and third party racks) with an adjustment range from 24" - 36" in depth. The ambidextrous cable management arm can be mounted on either the left or right side for improved cable management. HP ProLiant DL585 G5 in Telco Racks Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option kit from Rack Solutions.
HP ProLiant DL585 G5 rack models provide tool-free support for racks with square or round mounting holes (including Compaq/HP 7000, 9000, 10000, HP/E series, H9 series and third party racks) with an adjustment range from 24" - 36" in depth. The ambidextrous cable management arm can be mounted on either the left or right side for improved cable management. HP ProLiant DL585 G5 in Telco Racks Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option kit from Rack Solutions.
Software
Compatible operating systems
Microsoft® Windows® Server; Microsoft® Windows® Server Hyper V; Red Hat Enterprise Linux (RHEL); SUSE Linux Enterprise Server (SLES); Oracle Enterprise Linux (OEL); Solaris 10 for x86/x64 based Systems
Microsoft® Windows® Server; Microsoft® Windows® Server Hyper V; Red Hat Enterprise Linux (RHEL); SUSE Linux Enterprise Server (SLES); Oracle Enterprise Linux (OEL); Solaris 10 for x86/x64 based Systems
Microsoft® Windows® Server; Microsoft® Windows® Server Hyper V; Red Hat Enterprise Linux (RHEL); SUSE Linux Enterprise Server (SLES); Oracle Enterprise Linux (OEL); Solaris 10 for x86/x64 based Systems
Storage
Internal drive bays
Eight bay Small Form Factor (SFF) Serial Attached SCSI (SAS) drive cage
Eight bay Small Form Factor (SFF) Serial Attached SCSI (SAS) drive cage
Eight bay Small Form Factor (SFF) Serial Attached SCSI (SAS) drive cage
Optical drives
Slimline DVD/CD-RW Drive Standard on all models - ejectable for security and serviceability
Slimline DVD/CD-RW Drive (8X/24X) (ejectable)
Slimline DVD/CD-RW Drive (8X/24X) (ejectable)
Flexible disk drive
1.44 MB Diskette Drive bay available
1.44 MB Diskette Drive bay available
1.44 MB Diskette Drive bay available
Included hard drives
None Included
None Included
Internal drives
No hard disk drive in standard configuration
No hard disk drive in standard configuration
No hard disk drive in standard configuration
Hard disk drive speed
Not applicable
Not applicable
Not applicable
Optical drive type
Slimline DVD/CD-RW Drive Standard on all models - ejectable for security and serviceability
Slimline DVD/CD-RW Drive (8X/24X) (ejectable)
Slimline DVD/CD-RW Drive (8X/24X) (ejectable)
Storage controller
HP Smart Array P400/256 MB Controller (in PCI-Express slot 9); HP Smart Array P400/512 MB Controller with BBWC (in PCI-Express slot 9)
HP Smart Array P400/512 MB Controller with BBWC
HP Smart Array P400/512 MB Controller with BBWC
System
Form factor chassis
4U Rack
4U Rack
4U Rack
Form factor
4U Rack
4U Rack
4U Rack
Manageability features
HP Systems Insight Manager; SmartStart; Redundant ROM; Remote Flash ROM; Management Agents; Integrated Management Log (IML); Automatic Server Recovery-2 (ASR-2); ROM-Based Setup Utility (RBSU); Dynamic Sector Repairing (with Smart Array Controllers); Drive Parameter Tracking (with Smart Array Controllers); Pre-Failure Warranty (covers processors, SAS hard drives and memory); Redundant/adaptive load balancing NIC Support
HP Systems Insight Manager; SmartStart; Redundant ROM; Remote Flash ROM; Management Agents; Integrated Management Log (IML); Automatic Server Recovery-2 (ASR-2); ROM-Based Setup Utility (RBSU); Dynamic Sector Repairing (with Smart Array Controllers); Drive Parameter Tracking (with Smart Array Controllers); Pre-Failure Warranty (covers processors, SAS hard drives and memory); Redundant/adaptive load balancing NIC Support
HP Systems Insight Manager; SmartStart; Redundant ROM; Remote Flash ROM; Management Agents; Integrated Management Log (IML); Automatic Server Recovery-2 (ASR-2); ROM-Based Setup Utility (RBSU); Dynamic Sector Repairing (with Smart Array Controllers); Drive Parameter Tracking (with Smart Array Controllers); Pre-Failure Warranty (covers processors, SAS hard drives and memory); Redundant/adaptive load balancing NIC Support
Security management
Power-on password; Keyboard password; Diskette drive control enable/disable; Diskette boot control enable/disable; External USB port enable/disable; Network Server Mode; Serial interface control; Administrator's password; Removable optical drive
Power-on password; Keyboard password; Diskette drive control enable/disable; Diskette boot control enable/disable; External USB port enable/disable; Network Server Mode; Serial interface control; Administrator's password; Removable optical drive
Power-on password; Keyboard password; Diskette drive control enable/disable; Diskette boot control enable/disable; External USB port enable/disable; Network Server Mode; Serial interface control; Administrator's password; Removable optical drive
Feature
Processors: Quad-Core AMD Opteron™ 8300 Series Processors; Up to 6MB shared L3 cache; Up to 3.1GHz clock speed; New Low-power HE options now available
Memory: Up to 256 GB of memory, supported by (32) slots of PC2-5300 or PC2-6400 registered DIMMs up to 800MHz
Storage Controller: HP Smart Array P400/256MB Controller (optional 512MB battery backed write cache); HP Smart Array P400/512MB BBWC Controller standard on some models
Internal Drive Support: Up to 2.4TB internal storage; Slimline optical drive bay, DVD/CD-RW standard on some models
Network Controller: Two embedded NC371i Multifunction Gigabit Network Adapters with TCP/IP Offload Engine, including support for Accelerated iSCSI through an optional Licensing Kit
Expansion Slots: 9 total slots: (3) x8 PCI-Express; (4) x4 PCI-Express; (2) PCI-X (100MHz); One slot populated with the Smart Array P400 Controller
Video Ports: One front and one rear video ports
USB Ports: (5) Total USB 2.0 Ports: (2) front; (2) rear; (1) internal; Redundancy: Redundant hot plug power supplies and fans
Management: HP Insight Control suite delivers essential management, including proactive health management, lights out remote control, optimization of power usage, rapid server deployment, performance analysis, vulnerability scanning and patch management and virtual machine management
Video
Video RAM
32MB DDR memory
32MB DDR memory
32MB DDR memory
Graphic subsystem name
Integrated ATI-RN50
Integrated ATI-RN50
 
 
Operating temperature range10° to 35° C
Acoustic pressure emissions58 dB(A)
Acoustic power emissions7.7 B(A)
Non-operating altitude9,144 m
 
 
Compliance industry standardsACPI 1.0a. Compliant; PCI 2.2 Compliant; PXE Support; WOL Support (with embedded NC371i Multifunction Gigabit Network Adapters); Physical Address Extension (PAE) Support; Microsoft® Logo certifications; USB 2.0 Support
 
 
Product weight36 kg
Product dimensions (W x D x H)48.3 x 67.3 x 17.6 cm
 
Legal Disclaimer

The information contained in this document is subject to change with or without notice. Hewlett Packard makes no warranty of any kind with respect to this information. Hewlett Packard specifically disclaims the implied warranty of merchantability and fitness for a particular purpose. Hewlett Packard shall not be liable for any direct, indirect, incidental, consequential, or other damage alleged in connection with the furnishing or use of this information.

 
Trademark

Microsoft and Windows NT are registered trademarks or trademarks of Microsoft Corporation in the U.S. and/or other countries. Novell and NetWare are registered trademarks or trademarks of Novell, Inc. Solaris is a registered trademark or trademark of Sun Microsystems, Inc., in the U.S. and/or other countries. Linux is a registered trademark or trademark of Linus Torvalds in the U.S. and/or other countries. Red Hat is a registered trademark or trademark of Red Hat, Inc., in the U.S. and/or other countries. SuSE and its logo are registered trademarks or trademarks of SuSE AG in the U.S. and/or other countries. UNIX is a registered trademark of The Open Group in the U.S. and other countries. All other product names mentioned herein may be trademarks of their respective companies.

 

© 2002 Hewlett-Packard Company